Solvents and flushing fluids for Refrigeration & Air Conditioning piping GK-Lab?
Leak detectors & Dye - GK-Lab? for Refrigeration, Air Conditioning Auto A/C
Gas Leak Stop for Refrigerant Leakages GK-Lab?
Additives for PH Value, Moisture, Deposits of Oil and Refrigerant Gas Leak - GK-Lab?
Disinfectants and sanitizers with Bactericide and Virucidal Efficacy - Medical Devices
Auto - DPF Cleaning - Diesel Particulate Filters
Chemical Products
HVACR tools - Flaring tools and flare lubricant
HVACR tools - Tube cutters and deburrers
HVACR equipment - Various tools
Electronic Leak Detectors (infrared and heated diode), foaming detectors
Recovery Units for A1, A2L and A3 refrigerants (R290 propane)
Nitrogen and Nitrogen/Hydrogen Pressure Kit + Testers for Refrigeration and A/C systems
High vacuum pumps and hoses for HVACR systems
Digital Manifold Gauges, vacuum meters and bluetooth probes for pressure, temperature, humidity
Refrigerant digital weighing scales
Electronic Instrumentation for Diagnosis of Refrigeration & A/C systems
HVACR backpacks and tool carrying systems
Washing and cleaning units for Refrigeration & Air Conditioning systems
Adapters, connectors, depressors, shut-off, filters, valves GK Tools?
Sensors and control units for detecting leaks of refrigerant gases in the environment
T-PED Refrigerant cylinders (refillable)
Quick Couplers and Adapters - Automotive
N2, O2, C2H2 high pressure cylinders
G-TEC small cylinders (argon, CO2, blend Ar/CO2) and pressure gauges
Calibration and Check Service for F-Gas Instruments and Tools
Equipment
You can recover your password by entering the email you registered with and clicking on "RECOVER PASSWORD".
Total
$ 0.00
GK-Tools FlashGuard EX - Replacement Propane (R290) Sensor
Do you need to buy large quantities?
Replacement Combustible Gas / Propane (R290) Sensor for GK-TOOLS FlashGuard EX Detector
Original replacement catalytic sensor engineered for continuous detection and monitoring of combustible and explosive gases, specifically Propane (R290), within the GK-TOOLS FlashGuard EX portable detector.
With the transition toward environmentally friendly natural refrigerants (A3 / hydrocarbons), the adoption of propane (R290) is rapidly expanding across refrigerated display cases, heat pumps, and commercial systems. The sensor operates by measuring gas concentration as a percentage of the Lower Explosive Limit (LEL, 2.2% vol for R290).
Catalytic combustion sensors may experience drift over time or degradation due to prolonged exposure to high gas concentrations or catalytic poisons. Periodic replacement with an original component restores instrument response time, measurement accuracy, and operator safety.
Compatibility: GK-TOOLS FlashGuard EX portable multi-gas detector
Technology: High-sensitivity catalytic combustion
Measuring range: 0 – 100% LEL
Main Features
Technical Specifications
| Parameter | Detail / Value |
|---|---|
| Primary target gas | Propane (R290) / Combustible gases (LEL) |
| Detection principle | Catalytic combustion (pellistor) |
| Standard measuring range | 0 – 100% LEL |
| Resolution | 1% LEL |
| Instrument accuracy | ≤ ±3% Full Scale (F.S.) |
| Warm-up time | 90 seconds |
| Sampling method | Diffusion |
| Operating temperature | -20 °C to +50 °C |
| Operating humidity | 10 – 95% RH (non-condensing) |
| Operating pressure | 86 – 106 kPa |
Installation and Maintenance Notes
Technical warning: Maintenance and component replacement must be carried out by trained technicians in accordance with applicable safety regulations. Avoid contact with silicone compounds or airborne poisons that can permanently deactivate catalytic beads. Following sensor replacement, perform zero calibration in clean air followed by span calibration using appropriate calibration gas at the specified flow rate (200–500 ml/min) before field deployment.
| EAN | n.d. |
| Cylinder/Container size | Non Applicabile |
| Package weight | 0.3 Kg. |
| Item number | F-AF-SC-EX-SEN-R290 |
| Packaging | Cardboard box |
SAMON GS230-HFC: detection unit with built-in sensor, for synthetic refrigerants A1 and A2L (HFC including R32 and HFO) - unit with relay output and semiconductor sensor (SC)
SAMON GSR230-HFC: detection unit with remote sensor, for synthetic refrigerants A1 and A2L (HFC including R32 and HFO) - unit with relay output and semiconductor sensor (SC)
SAMON GXR230-HFC: ATEX detection unit with remote sensor, for synthetic refrigerants A2L (HFO and HFC included R32) - unit with relay output and semiconductor sensor (SC)
SAMON GXR230-HC: ATEX detection unit with remote sensor, for propane R290 and HC - unit with relay output and semiconductor sensor (SC)
SAMON GSLS230-CO2-10000: detection unit with built-in sensor and light + acoustic alarm, for carbon dioxide CO2 (R744) - unit with relay output and IR sensor (NDIR)
SAMON MPU4C: MPU control unit - 4-channel multi-zone control unit with light + acoustic alarm (for HFC, HFO and CO2) - unit with relay output, connectable to external sensors (supplied separately)
SAMON MP-DS (HFC/HFO/R32) – Detector for synthetic refrigerants for connection to MPU control panel - semiconductor sensor (SC)
SAMON MPS (CO2) – Carbon dioxide CO2 detector (R744) for connection to MPU control panel - IR sensor (NDIR)
SAMON GEX (R290 and HC) – Detector for R290 and hydrocarbons, for connection to MPU power plant - semiconductor sensor (SC)
GK-Tools FlashGuard EX - Portable ATEX Detector for Propane R290 (0-100% LEL) and Oxygen (0-30% VOL)
GK-Tools FlashGuard EX - Replacement Oxygen Sensor