Assorted chemical kit for cleaning of evaporators and condensers
Secondary fluids - GLYCOLS GK Lab?
Solvents and flushing fluids for Refrigeration & Air Conditioning piping GK Lab?
Leak detectors & Dye - GK Lab? for Refrigeration, Air Conditioning Auto A/C
Gas Leak Stop for Refrigerant Leakages GK Lab?
Additives for PH Value, Moisture, Deposits of Oil and Refrigerant Gas Leak - GK Lab?
Disinfectants and sanitizers with Bactericide and Virucidal Efficacy - Medical Devices
Auto - DPF Cleaning - Diesel Particulate Filters
Leak Stopper for Vehicles Cooling System
Chemical Products
HVACR tools - Flaring tools and flare lubricant
HVACR tools - Tube cutters and deburrers
Electronic Leak Detectors (infrared and heated diode), foaming detectors
Recovery Units for A1, A2L and A3 refrigerants (R290 propane)
Nitrogen and Nitrogen/Hydrogen Pressure Kit + Testers for Refrigeration and A/C systems
High vacuum pumps and hoses for HVACR systems
Digital Manifold Gauges, vacuum meters and bluetooth probes for pressure, temperature, humidity
Refrigerant digital weighing scales
Electronic Instrumentation for Diagnosis of Refrigeration & A/C systems
HVACR tool backpacks (original Fieldpiece)
Charging and recovery hoses for refrigerants
Refrigeration oil charging pump for HVACR systems
Washing and cleaning units for Refrigeration & Air Conditioning systems
Adapters, connectors, depressors, shut-off, filters, valves GK Tools?
Sensors and control units for detecting leaks of refrigerant gases in the environment
T-PED Refrigerant cylinders (refillable)
Quick Couplers and Adapters - Automotive
N2, O2, C2H2 high pressure cylinders
G-TEC small cylinders (argon, CO2, blend Ar/CO2) and pressure gauges
Calibration and Check Service for F-Gas Instruments and Tools
Equipment
You can recover your password by entering the email you registered with and clicking on "RECOVER PASSWORD".
Total
$ 0.00
R434A 100% Reclaimed (meets AHRI-700 quality standards) in T-PED returnable Roll Drum 920 Lt - 830 kg
Do you need to buy large quantities?
R434A Refrigerant Gas Reclaimed at the GeneralGas site of Cernusco sul Naviglio, authorized by the Ministry of the Environment with official Program Agreement.
Reclamation carried out in accordance with the European Regulation F-Gas No 517/2014, quality of reclaimed R434A meets AHRI700-2017 standard (characteristics equivalent to those of the virgin product).
The reclaimed gas supplied by GeneralGas is labeled under RE 517/2014 with the indication that the substance has been properly reclaimed, indications on the batch number and the name and address of the regeneration site.
TECHNICAL NOTE:
As of 01/01/2020, the systems operated with gas type R404A/R507/R422D (i.e. with a value of GWP > 2.500), having a refrigerant charge of more than 40 Ton CO2 (equivalent, for example, to 10,2 kg of R404A), it will no longer be possible to use virgin gas in service or maintenance, as required by the current F-Gas regulation (EU Regulation 517/2014 art 13 paragraph 3).
The above legislation expressly prohibits the use of virgin gases, so any stock of such refrigerants (purchased before that date) will no longer be able to be used. In the absence of preventive retrofits (extraordinary maintenance) that provide for the replacement of the above refrigerants with more environmentally friendly refrigerants (e.g. HFO-based refrigerant mixtures, such as R448A-R449A-R452A etc. defined Low GWP, and in any case with GWP > 2 500), the use of reclaimed refrigerants is still possible in service or maintenance.
The use of regenerated refrigerant gas is permitted for a wide period, i.e. until 2030, as per the provisions contained in Regulation (EU) n ro 517/2014 art 13 paragraph 3 letters a) and b)
The reclaimed refrigerant has the same chemical composition and performance as virgin gas, perfectly corresponding to american AHRI700-2017 standards, universally recognized as a qualitative reference; reclaimed gas is obtained from industrial chemical processes, which use as a raw material waste made from refrigerant gases; its production is the prerogative of plants that are authorized by the Ministry of the Environment to treat waste.
The refrigerant for retrofitting flooded systems
Kryon® 434A is a mixture of refrigerant gases developed to retrofit flooded systems running with R-22. Kryon® 434A properties can solve problems that may occur when retrofitting flooded systems with R-507. In this case, in fact, the substitution of both the electric engine and the condenser is necessary.
Recommended Lubricants
Kryon® 434A is compatible both with traditional lubricants (mineral oil and alkylbenzene oil) and with new lubricants (polyol esters).
EAN | n.d. |
ASHRAE Number | R-434A |
ASHRAE Flammability Classification | A1 |
Contents | 830.00 kg |
Cylinder/Container size | 920 liters |
Packaging Overall Dimensions | dia. 800 x 2250 (h) mm. |
Package weight | 1390 Kg. |
Valve Type | Double Phase (vapour + liquid) |
Valve Outlet | W 21,7 x 1/14" |
Item number | F-GF-R434A-FU-R |
Packaging | Steel tank |
Data sheet | Signup or Signin for Download |
Material Safety Data Sheet | Signup or Signin for Download |